RPP / PDU
CMS 7000 & CMS 8000 are the 2 Smart Sensor monitoring Systems, which enable the user to monitor 96 Branches in one segment.
Software : Built-in Webserver along with
Protocols : Rs485/Modbus TCP-IP, SNMP – Encrypted V3
The CMS 700 is communicable to all BMS Software’s & Schneider PMS
Software : Built-in Webserver along with
Protocols : Rs485/Modbus TCP-IP, SNMP – Encrypted V3
The CMS 700 is communicable to all BMS Software’s & Schneider PMS
- Live thermographic imaging facilities incorporated as standard
- Certified plug-in MCCB (AVAILABLE UPON REQUEST)
- Iso-ground bars available
- Fixed or mobile construction available (depending on size)
- 200% neutral busbar Standard
- Clean earth bars standard.
- Underfloor gland boxes available upon request. Standard product comes with laser knockout for standard cable entry for multiple out going circuits.
- Double front outer doors offered as standard.
- Certified to 61439-2 up to 50kA/1s with solutions available up to 1250A
- Pre-wired to separate the distribution terminal section Optional.
- Built-in cable management system to assist in the termination of outgoing cables
- BUILT IN software to set thresholds for customer contract requirements and raise alarms over the mail to Skip level management for analysis and control.
- A range of other monitoring devices can be integrated upon request such as Schneider / Elmeasure/ ECOM’s own BCPM meter is very efficient and versatile.
- Thermal imaging grids via CNC cluster punched adjacent to all critical terminations.
- Seismic rated enclosure.
Key Features :
Smart Benefits
- Reduced footprint designs for minimal space availability and tailored designs for extreme space constraints
- Fully bolted cubicle system with circuit breakers mounted behind lockable outer doors with a three-point catch system for safety and to prevent unauthorized operation of RPP devices.
- Control and metering sections can include various control, indication and metering elements to your specification.
- Placement of the RPP can be anywhere in the datacenter white tile area to reduce the out going cable laying and reduce the Power distribution copper cable length in kilometers.
Construction | To IEC-61439-2, up to Form 2B |
---|---|
Busbar System Current Rating | 100A to 1250A |
Busbar System Short Circuit Rating | Up to 50kA/1s |
Voltage Ratings | 400V / 690V |
Cable Access | Top or bottom access. |
Ingress protection | IP4X |
Panel Colour 7035 Standard, Other colours available upon request | Our construction features doesn’t involve any welding anywhere due to this we are able to offer all types of finishes like Glossy or matt or RAL finishes depending upon customer requirements. |